The xilinx_can driver performs a software reset when an RX overrun is detected. This causes the device to enter Configuration mode where no messages are received or transmitted. The documentation does not mention any need to perform a reset on an RX overrun, and testing by inducing an RX overflow also indicated that the device continues to work just fine without a reset. Remove the software reset. Tested with the integrated CAN on Zynq-7000 SoC. Fixes: b1201e44f50b ("can: xilinx CAN controller support") Signed-off-by: Anssi Hannula <anssi.hannula@xxxxxxxxxx> Cc: <stable@xxxxxxxxxxxxxxx> --- drivers/net/can/xilinx_can.c | 1 - 1 file changed, 1 deletion(-) diff --git a/drivers/net/can/xilinx_can.c b/drivers/net/can/xilinx_can.c index c71a035..ddb3287 100644 --- a/drivers/net/can/xilinx_can.c +++ b/drivers/net/can/xilinx_can.c @@ -600,7 +600,6 @@ static void xcan_err_interrupt(struct net_device *ndev, u32 isr) if (isr & XCAN_IXR_RXOFLW_MASK) { stats->rx_over_errors++; stats->rx_errors++; - priv->write_reg(priv, XCAN_SRR_OFFSET, XCAN_SRR_RESET_MASK); if (skb) { cf->can_id |= CAN_ERR_CRTL; cf->data[1] |= CAN_ERR_CRTL_RX_OVERFLOW; -- 2.8.3 -- To unsubscribe from this list: send the line "unsubscribe stable" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html