[RESEND] thermal: hwmon: Properly report critical temperature in sysfs

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



In the critical sysfs entry the thermal hwmon was returning wrong
temperature to the user-space.  It was reporting the temperature of the
first trip point instead of the temperature of critical trip point.

For example:
	/sys/class/hwmon/hwmon0/temp1_crit:50000
	/sys/class/thermal/thermal_zone0/trip_point_0_temp:50000
	/sys/class/thermal/thermal_zone0/trip_point_0_type:active
	/sys/class/thermal/thermal_zone0/trip_point_3_temp:120000
	/sys/class/thermal/thermal_zone0/trip_point_3_type:critical

Since commit e68b16abd91d ("thermal: add hwmon sysfs I/F") the driver
have been registering a sysfs entry if get_crit_temp() callback was
provided.  However when accessed, it was calling get_trip_temp() instead
of the get_crit_temp().

Fixes: e68b16abd91d ("thermal: add hwmon sysfs I/F")
Cc: <stable@xxxxxxxxxxxxxxx>
Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx>
---
 drivers/thermal/thermal_hwmon.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/thermal/thermal_hwmon.c b/drivers/thermal/thermal_hwmon.c
index c41c7742903a..2dcd4194d103 100644
--- a/drivers/thermal/thermal_hwmon.c
+++ b/drivers/thermal/thermal_hwmon.c
@@ -98,7 +98,7 @@ temp_crit_show(struct device *dev, struct device_attribute *attr, char *buf)
 	int temperature;
 	int ret;
 
-	ret = tz->ops->get_trip_temp(tz, 0, &temperature);
+	ret = tz->ops->get_crit_temp(tz, &temperature);
 	if (ret)
 		return ret;
 
-- 
2.9.3

--
To unsubscribe from this list: send the line "unsubscribe stable" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux Kernel]     [Kernel Development Newbies]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite Hiking]     [Linux Kernel]     [Linux SCSI]