[ 42/79] powerpc/eeh: Dont check RTAS token to get PE addr

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



3.9-stable review patch.  If anyone has any objections, please let me know.

------------------

From: Gavin Shan <shangw@xxxxxxxxxxxxxxxxxx>

commit b8b3de224f194005ad87ede6fd022fcc2bef3b1a upstream.

RTAS token "ibm,get-config-addr-info" or ibm,get-config-addr-info2"
are used to retrieve the PE address according to PCI address, which
made up of domain/bus/slot/function. If we don't have those 2 tokens,
the domain/bus/slot/function would be used as the address for EEH
RTAS operations. Some older f/w might not have those 2 tokens and
that blocks the EEH functionality to be initialized. It was introduced
by commit e2af155c ("powerpc/eeh: pseries platform EEH initialization").

The patch skips the check on those 2 tokens so we can bring up EEH
functionality successfully. And domain/bus/slot/function will be
used as address for EEH RTAS operations.

Reported-by: Robert Knight <knight@xxxxxxxxxxxxx>
Signed-off-by: Gavin Shan <shangw@xxxxxxxxxxxxxxxxxx>
Tested-by: Robert Knight <knight@xxxxxxxxxxxxx>
Signed-off-by: Benjamin Herrenschmidt <benh@xxxxxxxxxxxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>

---
 arch/powerpc/platforms/pseries/eeh_pseries.c |   12 +++++-------
 1 file changed, 5 insertions(+), 7 deletions(-)

--- a/arch/powerpc/platforms/pseries/eeh_pseries.c
+++ b/arch/powerpc/platforms/pseries/eeh_pseries.c
@@ -83,7 +83,11 @@ static int pseries_eeh_init(void)
 	ibm_configure_pe		= rtas_token("ibm,configure-pe");
 	ibm_configure_bridge		= rtas_token("ibm,configure-bridge");
 
-	/* necessary sanity check */
+	/*
+	 * Necessary sanity check. We needn't check "get-config-addr-info"
+	 * and its variant since the old firmware probably support address
+	 * of domain/bus/slot/function for EEH RTAS operations.
+	 */
 	if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) {
 		pr_warning("%s: RTAS service <ibm,set-eeh-option> invalid\n",
 			__func__);
@@ -102,12 +106,6 @@ static int pseries_eeh_init(void)
 		pr_warning("%s: RTAS service <ibm,slot-error-detail> invalid\n",
 			__func__);
 		return -EINVAL;
-	} else if (ibm_get_config_addr_info2 == RTAS_UNKNOWN_SERVICE &&
-		   ibm_get_config_addr_info == RTAS_UNKNOWN_SERVICE) {
-		pr_warning("%s: RTAS service <ibm,get-config-addr-info2> and "
-			"<ibm,get-config-addr-info> invalid\n",
-			__func__);
-		return -EINVAL;
 	} else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE &&
 		   ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) {
 		pr_warning("%s: RTAS service <ibm,configure-pe> and "


--
To unsubscribe from this list: send the line "unsubscribe stable" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Index of Archives]     [Linux Kernel]     [Kernel Development Newbies]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite Hiking]     [Linux Kernel]     [Linux SCSI]