Re: [PATCH 3.8 1/3] ath9k_hw: fix calibration issues on chainmask that don't include chain 0

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



There is a regression introduced by this patch when power save is off on
the station for idle checks.
I have AR9590 station with rx and tx chain set to 0x1 connected
to legacy AP (based on Ar9390) with RF cable and 40dB attenuator.

Before this patch in connection polling the station was properly sending
null function to check whether AP is still there. After this patch it sends
broadcast probe request which is anyway wrong or some 16 or so packets
of random data (rarely). It manifests itself in lost connection because there
is no ack from AP which is expected for null function.

I have been following skb's up to the descriptor setting in ath9k and it was
all ok i.e. proper null function with valid addresses.

I have been bisecting it twice because it doesn't make much sense but maybe
it's a HW issue?


Wojtek
--
To unsubscribe from this list: send the line "unsubscribe stable" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html