From: Vasileios Amoiridis <vassilisamir@xxxxxxxxx> commit 262a6634bcc4f0c1c53d13aa89882909f281a6aa upstream. According to the datasheet, both pressure and temperature can go up to oversampling x32. With this option, the maximum measurement time is not 80ms (this is for press x32 and temp x2), but it is 130ms nominal (calculated from table 3.9.2) and since most of the maximum values are around +15%, it is configured to 150ms. Fixes: 8d329309184d ("iio: pressure: bmp280: Add support for BMP380 sensor family") Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx> Link: https://patch.msgid.link/20240711211558.106327-3-vassilisamir@xxxxxxxxx Cc: <Stable@xxxxxxxxxxxxxxx> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/iio/pressure/bmp280-core.c | 7 ++++--- 1 file changed, 4 insertions(+), 3 deletions(-) --- a/drivers/iio/pressure/bmp280-core.c +++ b/drivers/iio/pressure/bmp280-core.c @@ -1272,10 +1272,11 @@ static int bmp380_chip_config(struct bmp } /* * Waits for measurement before checking configuration error - * flag. Selected longest measure time indicated in - * section 3.9.1 in the datasheet. + * flag. Selected longest measurement time, calculated from + * formula in datasheet section 3.9.2 with an offset of ~+15% + * as it seen as well in table 3.9.1. */ - msleep(80); + msleep(150); /* Check config error flag */ ret = regmap_read(data->regmap, BMP380_REG_ERROR, &tmp); Patches currently in stable-queue which might be from vassilisamir@xxxxxxxxx are queue-6.11/iio-pressure-bmp280-fix-regmap-for-bmp280-device.patch queue-6.11/iio-pressure-bmp280-fix-waiting-time-for-bmp3xx-configuration.patch