Patch "bnx2x: Do not handle requests from VFs after parity" has been added to the 4.9-stable tree

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



This is a note to let you know that I've just added the patch titled

    bnx2x: Do not handle requests from VFs after parity

to the 4.9-stable tree which can be found at:
    http://www.kernel.org/git/?p=linux/kernel/git/stable/stable-queue.git;a=summary

The filename of the patch is:
     bnx2x-do-not-handle-requests-from-vfs-after-parity.patch
and it can be found in the queue-4.9 subdirectory.

If you, or anyone else, feels it should not be added to the stable tree,
please let <stable@xxxxxxxxxxxxxxx> know about it.



commit 2b82990fc403c4c44debf97f6ea94af103f76669
Author: Manish Chopra <manishc@xxxxxxxxxxx>
Date:   Wed Dec 11 09:59:55 2019 -0800

    bnx2x: Do not handle requests from VFs after parity
    
    [ Upstream commit 7113f796bbbced2470cd6d7379d50d7a7a78bf34 ]
    
    Parity error from the hardware will cause PF to lose the state
    of their VFs due to PF's internal reload and hardware reset following
    the parity error. Restrict any configuration request from the VFs after
    the parity as it could cause unexpected hardware behavior, only way
    for VFs to recover would be to trigger FLR on VFs and reload them.
    
    Signed-off-by: Manish Chopra <manishc@xxxxxxxxxxx>
    Signed-off-by: Ariel Elior <aelior@xxxxxxxxxxx>
    Signed-off-by: Jakub Kicinski <jakub.kicinski@xxxxxxxxxxxxx>
    Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>

diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
index ce8a777b1e97..8d17d464c067 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
@@ -9995,10 +9995,18 @@ static void bnx2x_recovery_failed(struct bnx2x *bp)
  */
 static void bnx2x_parity_recover(struct bnx2x *bp)
 {
-	bool global = false;
 	u32 error_recovered, error_unrecovered;
-	bool is_parity;
+	bool is_parity, global = false;
+#ifdef CONFIG_BNX2X_SRIOV
+	int vf_idx;
+
+	for (vf_idx = 0; vf_idx < bp->requested_nr_virtfn; vf_idx++) {
+		struct bnx2x_virtf *vf = BP_VF(bp, vf_idx);
 
+		if (vf)
+			vf->state = VF_LOST;
+	}
+#endif
 	DP(NETIF_MSG_HW, "Handling parity\n");
 	while (1) {
 		switch (bp->recovery_state) {
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
index 888d0b6632e8..7152a03e3607 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
@@ -139,6 +139,7 @@ struct bnx2x_virtf {
 #define VF_ACQUIRED	1	/* VF acquired, but not initialized */
 #define VF_ENABLED	2	/* VF Enabled */
 #define VF_RESET	3	/* VF FLR'd, pending cleanup */
+#define VF_LOST		4	/* Recovery while VFs are loaded */
 
 	bool flr_clnup_stage;	/* true during flr cleanup */
 
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
index c2d327d9dff0..27142fb195b6 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
@@ -2095,6 +2095,18 @@ static void bnx2x_vf_mbx_request(struct bnx2x *bp, struct bnx2x_virtf *vf,
 {
 	int i;
 
+	if (vf->state == VF_LOST) {
+		/* Just ack the FW and return if VFs are lost
+		 * in case of parity error. VFs are supposed to be timedout
+		 * on waiting for PF response.
+		 */
+		DP(BNX2X_MSG_IOV,
+		   "VF 0x%x lost, not handling the request\n", vf->abs_vfid);
+
+		storm_memset_vf_mbx_ack(bp, vf->abs_vfid);
+		return;
+	}
+
 	/* check if tlv type is known */
 	if (bnx2x_tlv_supported(mbx->first_tlv.tl.type)) {
 		/* Lock the per vf op mutex and note the locker's identity.



[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]