Hello All, resending it ... attachments seems to be creating some problem. I am seeing a weird problem with 2.6-stable3 when testing with polymix-4. During the first phase of testing the cache performs very well, but during the second phase everything seems to break apart drastically. I have attached the results. I can provide further data if needed. setup: -------- * polymix-4 * 1000 req/s * 2 x 6hours phases. * 2 clt/srv pair (regular ... Intel xeon 2.8GHz with 1GB ram). version: Squid Cache: Version 2.6.STABLE3 configure options: '--prefix=/usr/squid' '--exec-prefix=/usr/squid' '--sysconfdir=/usr/squid/etc' '--enable-snmp' '--enable-err-languages=English' '--enable-linux-netfilter' '--enable-dlmalloc' '--enable-async-io=24' '--enable-storeio=ufs,aufs,null' '--enable-linux-tproxy' '--enable-gnuregex' '--enable-internal-dns' '--enable-epoll' '--with-maxfd=32768' cache server: * 2x Dual Core AMD Opteron(tm) Processor 270 HE * 16GB RAM * 1x SATA 45 GB drive. Few observations: --------------------------- * It looks like that after the idle phase the cache just breaks completely. * The CPU utilization is 100% (even with epoll), during the first phase it seems to be about 70%. * The cache.log doesnt give any indication as to what is happening. Except messages like these. 2006/08/25 15:32:45| squidaio_queue_request: WARNING - Queue congestion. But these messages showed up during first phase as well and also for 2.5-S9 testing. * 2.5 Stable-9 performs poorly ( all [hit+miss] req. mean resp. time = 4 sec, normally its abt 1.5 sec ) at 1000 req/s but it doesnt break the way 2.6-S3 did. * I have tried the same test for a few times and everytime after the idle phase the problem starts. In fact, I have reduced the first phase to 3hrs and still the same thing happens. * vmstat shows very little free memory, but again that happens very early in the first phase itself. * The logs for the polyclts and polysrvs doesnt indicate anything wrong there, except that they complain about connection reset as shown below: 268.32| Connection.cc:485: error: 1204/1830647 (s104) Connection reset by peer 268.32| error: raw read failed 268.32| connection to 10.51.6.102:8080 failed after 1 reads, 1 writes, 1 xacts 268.35| i-top2 5015237 393.54 5733 2.36 40 4985 So I am not sure what happens during the idle-phase that everything break so drastically. Is it not able to recover or does it break down trying to recover ? I would appreciate any kind of help. Any suggestions or metrics I should look for to figure out the problem. Thanks for your time. -- Pranav ------------------------------ http://pd.dnsalias.org