Re: SCSI Hard Drive Issues Netra

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Jim Gifford wrote:
Since I tried working with 2.6.16 and 2.6.16.1, when I attempt to mount my scsi disks, I get invalid disk label. Switch back to 2.6.15.x, and the problem goes away. Any ideas suggestions, I'm stuck at this point to figure out what's wrong. Any help will be appreciated.

OK, here's what I've been able to find out about the issue investigating it a lot further. Some reason it's saying my drives have an improper checksum(See error message below).

I'm doing a build on my X1 to see if the issue also exists.

root:~# fdisk /dev/sda
Detected sun disklabel with wrong checksum.
Probably you'll have to set all the values,
e.g. heads, sectors, cylinders and partitions
or force a fresh label (s command in main menu)


--
----
Jim Gifford
maillist@xxxxxxxxx

-
To unsubscribe from this list: send the line "unsubscribe sparclinux" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html