Am 11.09.22 um 11:08 schrieb Gandalf Corvotempesta:
let's assume a 3 way mirror (raid1 with 3 disks) One disk got a bad sector detrcted by smartd what happens trying to read or write to that sector? is md smart enough to read from the other 2 disks and serve consistant data?
that's the whole point of RAID
in other words, can i delay the disk replacement for a couple of days
just throw it out of the array - on a RAID 1 with two disk you have still redundancy and i won't trust a disk which recognized that it has errors on it's own
(i've ordered the disk today, will came tuesday)?
what's the point of "can i delay" when you have no other options? :-)