Re: Reassembling Raid5 in degraded state

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 13/01/2020 17:31, Song Liu wrote:
Song, Neil,

Just a guess as to what went wrong, but the array event count does not
match the disk counts. Iirc this is one of the events that cause an
Which mismatch do you mean?

assemble to stop. Is it possible that a crash at the wrong moment could
interrupt an update and trigger this problem?
It looks like sdc1 failed first. Then sdd1 and sdf1 got events for sdc1 failed.
Based on super block on sdd1 and sdf1, we already have two failed drive,
so assemble stopped.

Does this answer the question?

Sorry yes it does. My fault for mis-reading the logs the OP sent.

Cheers.,
Wol



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]