Hi to all.
any equivalent to LSI Patrol Read ?
Here you can find a detailed description:
http://fibrevillage.com/storage/176-megaraid-patrol-read-detail

tl;dr:
This process causes the drives to read the data by issuing read-verify
commands. By using the read-verify command, the data from the drives
is not transferred to the MegaRAID adapter unless an error is detected
and reported by one or more drives included in the stripe. If a single
drive reports an error within the stripe, the read patrol function
initiates read commands to all the other stripe unit drives and the
data for this single failing stripe unit is recreated by the MegaRAID
adapter from the remaining data and parity stripe units.

I don't think it's the same as a standard consistency check, because
all LSI controller have both patrol read and consistency checks
features, so there should be a difference in this.
AFAIK, patrol read scan all sector of all disks, consistency check
only scan used sectors.
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]