Re: RAID6: "Bad block number requested"

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 11/06/18 16:06, James Bottomley wrote:
> Well, this is the problem: a 4k logical (presumably 4k physical) drive
> cannot be addressed in block sectors that are not divisible by 8.  This
> type of drive configuration is very unusual (although it was something
> we tested years ago before the industry realised it had to ship drives
> with 4k physical but 512 byte logical sectors because of the legacy
> problem).
I understood these drives were now becoming much more common, especially
enterprise-grade drives. I know there were problems switching from
512/512 drives to 512/4096, but as you say I thought they were pretty
much addressed.

I think it must be a couple of years ago now though, that I heard (on
LWN) enterprise drives were apparently switching over to 4096/4096. With
NO 512 emulation fall-back.

Cheers,
Wol
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]