Re: [PATCH] md-cluster: choose correct label when clustered layout is not supported

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 





On 01/23/2018 11:06 PM, Lidong Zhong wrote:
r10conf is already successfully allocated before checking the layout

Signed-off-by: Lidong Zhong <lzhong@xxxxxxxx>
---
  drivers/md/raid10.c | 2 +-
  1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/md/raid10.c b/drivers/md/raid10.c
index c131835cf008..c2b2fbeec7b2 100644
--- a/drivers/md/raid10.c
+++ b/drivers/md/raid10.c
@@ -3770,7 +3770,7 @@ static int raid10_run(struct mddev *mddev)
  		if (fc > 1 || fo > 0) {
  			pr_err("only near layout is supported by clustered"
  				" raid10\n");
-			goto out;
+			goto out_free_conf;
  		}
  	}

Thanks for catch it.
Reviewed-by: Guoqing Jiang <gqjiang@xxxxxxxx>

Regards,
Guoqing
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]