Re: 3-way mirror to RAID-6

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 08/01/18 11:34, Gandalf Corvotempesta wrote:
> So, which is the best procedure to follow to increse the total usable
> space, without loosing redundancy while the system is running ?
> 
> I would like to have some confirms from skilled users in this ML.
> On my own, i would replace one disk per time (fail+remove+add) and
> wait for resync to complete, then, resize the array:

Well, that's certainly not best practice!

If you can, you replace one disk at a time with --replace. That will
copy the drive in-place with *no* reduction in redundancy. Doing a
fail/remove removes one level of redundancy.

Okay, you need spare ports to do a --replace so it's not always
possible, but it's always desirable. And with enough spare ports, you
can replace more than one drive at once, again with NO loss of redundancy.

Cheers,
Wol
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]