For cluster scenario, add device is different with native raid. When a node issues adds a device, then the node will broadcast a message with UUID to other nodes in the cluster. If receiving node can find the device with the specific UUID, it must confirm the device, otherwise reports it is missing. Signed-off-by: Guoqing Jiang <gqjiang@xxxxxxxx> --- Makefile | 6 ++++-- udev-md-clustered-confirm-device.rules | 21 +++++++++++++++++++++ 2 files changed, 25 insertions(+), 2 deletions(-) create mode 100644 udev-md-clustered-confirm-device.rules diff --git a/Makefile b/Makefile index 021d3ad..0977f27 100644 --- a/Makefile +++ b/Makefile @@ -256,8 +256,10 @@ install-man: mdadm.8 md.4 mdadm.conf.5 mdmon.8 $(INSTALL) -D -m 644 md.4 $(DESTDIR)$(MAN4DIR)/md.4 $(INSTALL) -D -m 644 mdadm.conf.5 $(DESTDIR)$(MAN5DIR)/mdadm.conf.5 -install-udev: udev-md-raid-arrays.rules udev-md-raid-assembly.rules udev-md-raid-creating.rules - @for file in 01-md-raid-creating.rules 63-md-raid-arrays.rules 64-md-raid-assembly.rules ; \ +install-udev: udev-md-raid-arrays.rules udev-md-raid-assembly.rules udev-md-raid-creating.rules \ + udev-md-clustered-confirm-device.rules + @for file in 01-md-raid-creating.rules 63-md-raid-arrays.rules 64-md-raid-assembly.rules \ + 69-md-clustered-confirm-device.rules ; \ do sed -e 's,BINDIR,$(BINDIR),g' udev-$${file#??-} > .install.tmp.1 && \ $(ECHO) $(INSTALL) -D -m 644 udev-$${file#??-} $(DESTDIR)$(UDEVDIR)/rules.d/$$file ; \ $(INSTALL) -D -m 644 .install.tmp.1 $(DESTDIR)$(UDEVDIR)/rules.d/$$file ; \ diff --git a/udev-md-clustered-confirm-device.rules b/udev-md-clustered-confirm-device.rules new file mode 100644 index 0000000..3e5381e --- /dev/null +++ b/udev-md-clustered-confirm-device.rules @@ -0,0 +1,21 @@ +# do not edit this file, it will be overwritten on update + +SUBSYSTEM!="block", GOTO="clustermd_end" + +# handle md arrays +KERNEL!="md*", GOTO="clustermd_end" +ENV{DEVTYPE}!="disk", GOTO="clustermd_end" +ACTION!="change", GOTO="clustermd_end" +ENV{EVENT}!="ADD_DEVICE", GOTO="clustermd_end" +ENV{DEVICE_UUID}!="?*", GOTO="clustermd_end" +ENV{RAID_DISK}!="?*", GOTO="clustermd_end" + +# Based on the received UUID, node confirms the device if +# it is found by blkid, otherwise the node reports it is +# missing. +PROGRAM="BINDIR/blkid -o device -t UUID_SUB=$env{DEVICE_UUID}", ENV{.md.newdevice} = "$result" + +ENV{.md.newdevice}!="", RUN+="BINDIR/mdadm --manage $env{DEVNAME} --cluster-confirm $env{RAID_DISK}:$env{.md.newdevice}" +ENV{.md.newdevice}=="", RUN+="BINDIR/mdadm --manage $env{DEVNAME} --cluster-confirm $env{RAID_DISK}:missing" + +LABEL="clustermd_end" -- 2.10.0 -- To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html