Re: proactive disk replacement

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 





Am 21.03.2017 um 14:13 schrieb David Brown:
On 21/03/17 12:03, Reindl Harald wrote:

Am 21.03.2017 um 11:54 schrieb Adam Goryachev:
<snip>

In addition, you claim that a drive larger than 2TB is almost certainly
going to suffer from a URE during recovery, yet this is exactly the
situation you will be in when trying to recover a RAID10 with member
devices 2TB or larger. A single URE on the surviving portion of the
RAID1 will cause you to lose the entire RAID10 array. On the other hand,
3 URE's on the three remaining members of the RAID6 will not cause more
than a hiccup (as long as no more than one URE on the same stripe, which
I would argue is ... exceptionally unlikely).

given that when your disks have the same age errors on another disk
become more likely when one failed and the heavy disk IO due recovery of
a RAID6 with takes *many hours* where you have heavy IO on *all disks*
compared with a way faster restore of RAID1/10 guess in which case a URE
is more likely

additionally why should the whole array fail just because a single block
get lost? the is no parity which needs to be calculated, you just lost a
single block somewhere - RAID1/10 are way easier in their implementation

If you have RAID1, and you have an URE, then the data can be recovered
from the other have of that RAID1 pair.  If you have had a disk failure
(manual for replacement, or a real failure), and you get an URE on the
other half of that pair, then you lose data.

With RAID6, you need an additional failure (either another full disk
failure or an URE in the /same/ stripe) to lose data.  RAID6 has higher
redundancy than two-way RAID1 - of this there is /no/ doubt

yes, but with RAID5/RAID6 *all disks* are involved in the rebuild, with a 10 disk RAID10 only one disk needs to be read and the data written to the new one - all other disks are not involved in the resync at all

for most arrays the disks have a similar age and usage pattern, so when the first one fails it becomes likely that it don't take too long for another one and so load and recovery time matters
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]