Re: GRUB warning after replacing disk drive in RAID1

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 





Am 28.02.2017 um 22:01 schrieb Peter Sangas:
But I issue the grub command AFTER the re-sync is completed

output of "cat /proc/mdstat" and your environment missing!

* cat /proc/mdstat
* df -hT
* lsscsi
* lsblk

no pictures and interpretations, just copy&paste from the terminal (input as well as output)

please help others to help you

-----Original Message-----
From: Reindl Harald [mailto:h.reindl@xxxxxxxxxxxxx]
Sent: Tuesday, February 28, 2017 1:23 AM
To: linux-raid@xxxxxxxxxxxxxxx
Subject: Re: GRUB warning after replacing disk drive in RAID1

Am 28.02.2017 um 00:37 schrieb Peter Sangas:
I have a RAID1 with 3 disks sda,sdb,sdc.  After replacing sdc and
re-syncing it to the array I issued the following command to load grub
but I get this
warning:

grub-install /dev/sdc

Installing for i386-pc platform.
grub-install: warning: Couldn't find physical volume `(null)'. Some
modules may be missing from core image..
grub-install: warning: Couldn't find physical volume `(null)'. Some
modules may be missing from core image..
Installation finished. No error reported.

Does anyone know why I get this warning and how to avoid it

it's harmless and disappears after the resync finished
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]