Hi Neil, In a MDRAID derived work we found and fixed a data corruption bug. We think this also affect vanilla MDRAID, but we didn’t directly prove that by constructing a test to show the corruption. Following is the theoretical analysis, please kindly review and see if I missed something. To rebuild a stripe, MD checks whether array will be optimal after rebuild complete, if that’s true, we’ll mark the WIB bit to be cleared, the purpose is to enable “incremental rebuild”. The code section is like this: /* Need to check if array will still be degraded after recovery/resync * We don't need to check the 'failed' flag as when that gets set, * recovery aborts. */ for (i = 0; i < conf->raid_disks; i++) if (conf->disks[i].rdev == NULL) still_degraded = 1; The problem is that only checking rdev == NULL might not be enough. Suppose both 2 drives D0 and D1 failed and marked as Faulty; We immediately removed D0 from array, but because some lingering IO on D1, it remains in array with Faulty flags on. A new drive pulled in, rebuild against D0 starts. Now because no rdev is NULL, MD thinks array will be optimal. If some writes happened before rebuild reaches the region, their dirty bits in WIB will be cleared. When later add D1 back into array, we’ll skip rebuilding those stripes, thus data corruption. The attached patch (against 3.18.0-rc6) is supposed to fix this issue. Thanks Eric
Attachment:
0001-md-raid5-check-faulty-flag-for-array-status-during-r.patch
Description: Binary data