Hi,
I've did some Linux MD RAID 5 and 6 random write performance tests with
fio 2.1.2 (Flexible I/O tester) under Linux 3.12.4. However, the results
for RAID 6 show that writes to a single chunk in a stripe (chunk size is
64 KB) result in more than 3 reads in case of more than 6 drives (tested
with 7, 8, and 9 drives) in the array (see fio statistics below). It
seems like that in the event of updating one data chunk in a stripe, all
of the remaining data chunks are read.
By the way, in case of RAID 5 and 5 or more drives, the remaining chunks
seem not to be read when updating a single chunk in a stripe.
Here is the fio job description:
########
[global]
ioengine=libaio
iodepth=128
direct=1
continue_on_error=1
time_based
norandommap
rw=randwrite
filename=/dev/md9
bs=64k
numjobs=1
stonewall
runtime=300
[randwritesjob]
########
And, the mdadm commands that were used to create the RAID6 arrays:
6 drives:
mdadm --create /dev/md9 --raid-devices=6 --chunk=64 --assume-clean
--level=6 /dev/sds1 /dev/sdc1 /dev/sdd1 /dev/sde1 /dev/sdf1 /dev/sdx1
7 drives:
mdadm --create /dev/md9 --raid-devices=7 --chunk=64 --assume-clean
--level=6 /dev/sds1 /dev/sdc1 /dev/sdd1 /dev/sde1 /dev/sdf1 /dev/sdg1
/dev/sdx1
8 drives:
mdadm --create /dev/md9 --raid-devices=8 --chunk=64 --assume-clean
--level=6 /dev/sds1 /dev/sdc1 /dev/sdd1 /dev/sde1 /dev/sdf1 /dev/sdg1
/dev/sdh1 /dev/sdx1
9 drives:
mdadm --create /dev/md9 --raid-devices=9 --chunk=64 --assume-clean
--level=5 /dev/sds1 /dev/sdc1 /dev/sdd1 /dev/sde1 /dev/sdf1 /dev/sdg1
/dev/sdh1 /dev/sdn1 /dev/sdx1
In case of 6 drives the number of reads equals to the number of writes
(3 reads and 3 writes per chunk update):
Disk stats (read/write):
md9: ios=253/210879, merge=0/0
sdc: ios=105763/105167, merge=1586024/1577446
sdd: ios=105543/105414, merge=1582303/1581166
sde: ios=105585/105431, merge=1582110/1581422
sdf: ios=105401/105554, merge=1580325/1583232
sds: ios=105369/105535, merge=1580462/1582964
sdx: ios=105265/105642, merge=1578948/1584552
However, because reading the remaining 3 data chunks and reading one
data chunk and 2 parity chunks results in the same number of reads, it's
not clear which of the two variants is used for MD RAID6.
In case of 7 drives the number of reads seems to be 4 for each chunk update:
Disk stats (read/write):
md9: ios=249/203012, merge=0/0
sdc: ios=116110/86970, merge=1740493/1304459
sdd: ios=115974/87089, merge=1738768/1306256
sde: ios=115840/87219, merge=1736818/1308189
sdf: ios=115981/87090, merge=1738738/1306242
sdg: ios=116114/86894, merge=1741662/1303300
sds: ios=116044/86964, merge=1740614/1304337
sdx: ios=116176/86832, merge=1742593/1302371
In case of 8 drives the number of reads seems to increase to 5 for each
chunk update:
Disk stats (read/write):
md9: ios=249/193770, merge=0/0
sdc: ios=121322/72530, merge=1818647/1087889
sdd: ios=121010/72765, merge=1815182/1091398
sde: ios=121007/72815, merge=1814401/1092150
sdf: ios=121303/72512, merge=1818887/1087653
sdg: ios=121124/72648, merge=1816862/1089676
sdh: ios=121134/72645, merge=1816998/1089599
sds: ios=121134/72692, merge=1816231/1090337
sdx: ios=121022/72750, merge=1815408/1091172
And, in case of 9 drives the number of reads seems to increase to 6 for
each chunk update:
Disk stats (read/write):
md9: ios=80/10337, merge=0/0
sdc: ios=6855/3496, merge=102721/52425
sdd: ios=6876/3468, merge=103141/52005
sde: ios=6914/3446, merge=103471/51675
sdf: ios=6837/3522, merge=102331/52815
sdg: ios=6923/3422, merge=103815/51331
sdh: ios=6902/3442, merge=103530/51631
sdn: ios=6912/3448, merge=103440/51705
sds: ios=6976/3385, merge=104385/50760
sdx: ios=6935/3408, merge=104041/51105
To my mind, updating a single chunk in a RAID 6 with 6 or more drives
should not incur more than reading 3 chunks and writing 3 chunks. The
reason is that for overwriting a single chunk, it suffices to read the
old content of the chunk and the two corresponding parity chunks (P and
Q) in order to be able to calculate the new parity values. After that,
the new content of the updated data chunk is written along with the two
parity chunks. Perhaps, this behavior can be controlled by a
configuration parameter that I have not found yet.
Is anyone aware of this issue in MD RAID 6?
Thanks,
Nikolaus
--
Dipl.-Inf. Nikolaus Jeremic nikolaus.jeremic@xxxxxxxxxxxxxx
Universitaet Rostock Tel: (+49) 381 / 498 - 7635
Albert-Einstein-Str. 22 Fax: (+49) 381 / 498 - 7482
18059 Rostock, Germany wwwava.informatik.uni-rostock.de
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html