On Tue, 30 Apr 2013, Roberto Nunnari wrote:
You believe that this is not enough? What's the unit? milliseconds? # for x in /sys/block/sd[a-z] ; do cat $x/device/timeout ; done 30 30 30 30
The unit is in seconds, and yes, you want the drive to report an error before the kernel drops it, so 180 seconds is sufficient for most drives to give up and return a read error.
-- Mikael Abrahamsson email: swmike@xxxxxxxxx -- To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html