Re: replacing drives

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Tue, 30 Apr 2013, Roberto Nunnari wrote:

You believe that this is not enough? What's the unit? milliseconds?
# for x in /sys/block/sd[a-z] ; do cat $x/device/timeout ; done
30
30
30
30

The unit is in seconds, and yes, you want the drive to report an error before the kernel drops it, so 180 seconds is sufficient for most drives to give up and return a read error.

--
Mikael Abrahamsson    email: swmike@xxxxxxxxx
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]