Re: help: re-add needed after each reboot

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



D. Lin wrote:
Hi,

I am running 3.2.0 (ubuntu 12.04). My raid5 has 3 disks (sd[cbd]1) and no
spares. The system boots off a non-raid device and auto discovers and
mounts the raid device.

For some reason, sdc1 is not automatically detected and is always missed
on each boot. I have to re-add it back. What could be causing this?

This did not happen while I was running 2.6.38.

Unless you can get back to that kernel and the problem goes away, that's likely to be irrelevant.

If this only happens on power cycle I would suspect a slow spin-up on one drive, otherwise that's not it. Be any chance is that drive, and only that drive, set to spin down when not in use?

Check partition types. That shouldn't be an issue, but check anyway.

Have you run SMART on the drives? Ignore this idea if you don't see the problem when booting off the old kernel. Just because you changed software and the problem occurred, don't completely rule out hardware, or a subtle config problem.

--
Bill Davidsen <davidsen@xxxxxxx>
  "We have more to fear from the bungling of the incompetent than from
the machinations of the wicked."  - from Slashdot
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]


  Powered by Linux