Re: polling mdX/md/degraded in sysfs

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



2012/1/9 Mikhail Balabin <mbalabin@xxxxxxxxx>:
> 2012/1/9 NeilBrown <neilb@xxxxxxx>:
>> On Sun, 8 Jan 2012 11:06:59 +0200 Alexander Lyakas <alex.bolshoy@xxxxxxxxx>
>> wrote:
>>
>>> Hi,
>>> well, at least according to 2.6.38-8 kernel code, this attribute is
>>> notified in 3 cases:
>>> # When the array is started (e.g., via RUN_ARRAY ioctl)
>>> # When "reshape" is initiated via sysfs
>>> # When a spare is activated after successful completion of
>>> resync/recover/check/replair
>>>
>>
>> Hmm... it really should notify when a disk fails.
>>
>> Mikhail: could you please test if this patch makes it work better for you?
>
> Ok, I'll try to test the patch against 3.2 today.
>
>> Thanks,
>> NeilBrown
>
> Mikhail Balabin

The patch have fixed the issue. I suppose it should go to the mainline.

Alexander, Neil, thanks for your efforts.

Mikhail Balabin
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]