Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



----- Original Message -----
> From: "Andrei Warkentin" <awarkentin@xxxxxxxxxx>
> To: "NeilBrown" <neilb@xxxxxxx>
> Cc: linux-raid@xxxxxxxxxxxxxxx, "Andrei Warkentin" <andreiw@xxxxxxxxxx>
> Sent: Tuesday, October 18, 2011 4:06:05 PM
> Subject: Re: [PATCH] MD: Allow restarting an interrupted incremental recovery.
> 
> Hi Neil,
> 
> ----- Original Message -----
> > From: "Andrei Warkentin" <awarkentin@xxxxxxxxxx>
> > To: "NeilBrown" <neilb@xxxxxxx>
> > Cc: linux-raid@xxxxxxxxxxxxxxx, "Andrei Warkentin"
> > <andreiw@xxxxxxxxxx>
> > Sent: Tuesday, October 18, 2011 1:07:24 PM
> > Subject: Re: [PATCH] MD: Allow restarting an interrupted
> > incremental recovery.
> > 
> > > Also I realised that clearing saved_raid_disk when an array is
> > > not
> > > degraded
> > > is no longer enough.  We also need to clear it when the device
> > > becomes
> > > In_sync.
> > > Consider a 3-drive RAID1 with two drives missing.  You add back
> > > one
> > > of them
> > > and when it is recovered it needs saved_raid_disk cleared so that
> > > the
> > > superblock gets written out.
> > > 
> > > So below is what I applied.
> > > 
> > 
> > Wouldn't all drives being In_sync imply the array is not degraded -
> > i.e. can the
> > check for a degraded array be omitted then, at all? I.e. if after
> > the
> > resync the
> > In_sync bit is set - drop saved_raid_role.
> > 
> 
> Come to think of it - checking for !mddev->degraded might not be a
> good idea at all. After all, you
> could imagine a situation where in a RAID1 array with A and B, A is
> recovered from B and then B goes away before
> the SBs are flushed due to resync finishing - you would still want
> A's SB to be flushed, even if array is degraded.
> 
> Otherwise you'll end up with another incremental rebuilding A, and
> lost/inconsistent data after array became degraded (since it was
> going to A, but we never wrote out its SB, since array is degraded).
> 

Errr, I confused myself. This is exactly why you added the check for In_sync.
OTOH, isn't the mddev->degraded now superflous - i.e. if all disks are In_sync,
there is no need to check for degraded, right?

A
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]