Re: HW Raid Question

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, 19 Oct 2009, Pawe? Brodacki wrote:

You cannot grow an array on ServeRAID by replacing smaller drives with bigger ones. If you do such a replacement the drive size will be "clipped". That means if you have 5x36 GB drive, remove one, and put in a 140 GB drive, only 36 GB out of it will be used. I'm pretty sure this will also happen if you try to extend the array by adding bigger drives to the already existing array.

The only way is to tear the array down and re-define it with bigger drives.

Just to give input from some other vendor, when I asked 3ware the same question they said they could take some dump from the config of the 3ware controller, process it, and then you put it back in, and it would support the larger drives. Ie, this seems to be something the hw raid crowd doesn't feel is an important method of storage migration to support.

--
Mikael Abrahamsson    email: swmike@xxxxxxxxx
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]