>> + blk_queue_io_opt(mddev->queue, chunk_size * (mddev->raid_disks >>
>>  	blk_queue_io_opt(mddev->1));

Neil>  ">> 1" is wrong.  A raid10 may have more than 2 copies for each
Neil>  block.

I recall pondering when I wrote that.  Never got around to revisiting
the issue.  Your RAID10 implementation is a bit hipper than most :)


Neil>  This calculation needs to be a bit more subtle and take about of
Neil>  the particular layout (near, offset, or far).

Why would layout interfere with preferred I/O size?

How about:

    if (conf->raid_disks % conf->copies)
	blk_queue_io_opt(mddev->queue, chunk_size * conf->raid_disks);
    else
	blk_queue_io_opt(mddev->queue, chunk_size *
			 (conf->raid_disks / conf->copies));

I.e.:

2 drives, 2 copies: a1 a1       optimal I/O = 1 * chunk_size

3 drives, 2 copies: a1 a1 a2
                    a2 a3 a3    optimal I/O = 3 * chunk_size

4 drives, 2 copies: a1 a1 a2 a2	optimal I/O = 2 * chunk_size

4 drives, 3 copies: a1 a1 a1 a2
                    a2 a2 a3 a3
                    a3 a4 a4 a4 optimal I/O = 4 * chunk_size

And so on.  Does that make sense?  I.e. we try to keep all drives
equally busy.


Neil> You seem to be treating raid4 like raid6 :-)

Whoops.  I always forget about raid4.  Fixed.

-- 
Martin K. Petersen	Oracle Linux Engineering
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]


  Powered by Linux