Re: Bug with RAID1 hot spares?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Friday October 20, chase.venters@xxxxxxxxxxxx wrote:
> Greetings,
> 	I was just testing a server I was about to send into production on kernel 
> 2.6.18.1. The server has three SCSI disks with "md1" set to a RAID1 with 2 
> mirrors and 1 spare. The mirrors are sda3 and sdb3, spare is sdc3. I manually 
> failed sdb3, and as expected, sdc3 was activated. Strangely 
> enough, /proc/mdstat did not indicate that sdc3 was being synced. I thought 
> these spares weren't kept mirrored until needed?

Correct.  They are not kept mirrored.

> 	So there's definitely something odd happening here... why did no resync to 
> the sdc3 spare start when I failed sdb3?

yes... can you check that this fixes it please?
Thanks,
NeilBrown

Signed-off-by: Neil Brown <neilb@xxxxxxx>

### Diffstat output
 ./drivers/md/md.c |    1 +
 1 file changed, 1 insertion(+)

diff .prev/drivers/md/md.c ./drivers/md/md.c
--- .prev/drivers/md/md.c	2006-10-23 12:09:08.000000000 +1000
+++ ./drivers/md/md.c	2006-10-23 14:10:46.000000000 +1000
@@ -2003,6 +2003,7 @@ static mdk_rdev_t *md_import_device(dev_
 	kobject_init(&rdev->kobj);
 
 	rdev->desc_nr = -1;
+	rdev->saved_raid_disk = -1;
 	rdev->flags = 0;
 	rdev->data_offset = 0;
 	rdev->sb_events = 0;
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]