Re: "command 0x25 timeout, stat 0x50 host_stat 0x1"

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Sat, Jun 03, 2006 at 05:40:07PM -0700, Patrik Jonsson wrote:
> Andy Smith wrote:
> > Booting the system with a Knoppix 4 DVD (kernel version 2.6.12), I
> > went to set up the md arrays and got a syslog full of this:
> > 
> > ata2: command 0x25 timeout, stat 0x50 host_stat 0x2
> > ata1: command 0x25 timeout, stat 0x50 host_stat 0x1
> > ata1: command 0x25 timeout, stat 0x50 host_stat 0x1
> > ata1: command 0x25 timeout, stat 0x50 host_stat 0x2
> > 
> > as well as a painfully slow (~100K/sec) initial resync.

[...]

> I shot in the dark, but cabling might be a culprit. I've had some issues
> with cables, both with the ridiculously unreliable SATA connectors
> coming out a little as well as with cables which must have been
> insufficiently shielded.

It actually seems to have been power related.  I'm using Icydock
SATA disk chassis which have two molex power connectors and one SATA
power connector for 3 drives.  I had thought that the differing
types made it an either/or situation, i.e. that it would be happy
with the two molex.  The "documentation" is what I would charitably
call terse.  Anyway after putting in the 3rd SATA power this problem
went away.

Cheers,
Andy

Attachment: signature.asc
Description: Digital signature


[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]