[PATCH md 003 of 14] Make sure read error on last working drive of raid1 actually returns failure.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



We are inadvertently setting the R1BIO_Uptodate bit on read errors
when we decide not to try correcting (because there are no other
working devices).  This means that the read error is reported to
the client as success.

Signed-off-by: Neil Brown <neilb@xxxxxxx>

### Diffstat output
 ./drivers/md/raid1.c |    3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff ./drivers/md/raid1.c~current~ ./drivers/md/raid1.c
--- ./drivers/md/raid1.c~current~	2005-11-28 17:20:37.000000000 +1100
+++ ./drivers/md/raid1.c	2005-11-29 10:28:21.000000000 +1100
@@ -284,7 +284,8 @@ static int raid1_end_read_request(struct
 		 * user-side. So if something waits for IO, then it will
 		 * wait for the 'master' bio.
 		 */
-		set_bit(R1BIO_Uptodate, &r1_bio->state);
+		if (uptodate)
+			set_bit(R1BIO_Uptodate, &r1_bio->state);
 
 		raid_end_bio_io(r1_bio);
 	} else {
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]