Re: RAID5 - 2nd drive died whilst waiting for RMA

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



David Greaves wrote:

So my RAID5 has 2 dead drives and is toasted :(
I had a few smaller disks on another machine which I lvm'ed together to do a backup - but I could only fit about a quarter of my data there. I'd *really* like not to have lost all this stuff.


However I do now have a 'good' drive.
Can I dd the newly dead drive (bear in mind it probably only has a bad block or two) onto the new drive and come back up in degraded mode?


I've had a think and this is my plan.... comments appreciated.

Currently:
/dev/md0:
       Version : 00.90.01
 Creation Time : Sat Jun  5 18:13:04 2004
    Raid Level : raid5
    Array Size : 980446208 (935.03 GiB 1003.98 GB)
   Device Size : 245111552 (233.76 GiB 250.99 GB)
  Raid Devices : 5
 Total Devices : 4
Preferred Minor : 0
   Persistence : Superblock is persistent

   Update Time : Fri Nov 12 09:46:53 2004
         State : clean, degraded
Active Devices : 3
Working Devices : 3
Failed Devices : 1
 Spare Devices : 0

        Layout : left-symmetric
    Chunk Size : 128K

   Number   Major   Minor   RaidDevice State
      0       0        0       -1      removed
      1       8       33        1      active sync   /dev/sdc1
      2       8       17        2      active sync   /dev/sdb1
      3       0        0       -1      removed
      4       3       65        4      active sync   /dev/hdb1
      5       8        1       -1      faulty   /dev/sda1
          UUID : 19779db7:1b41c34b:f70aa853:062c9fe5
        Events : 0.4443578

so, the plan in order to try and extract data:
* insert new drive as /dev/sdd1
* dd if=/dev/sda1 of=/dev/sdd1
* mdadm /dev/md0 --remove /dev/sda1
* physically swap /dev/sda and /dev/sdd so /dev/sdd
* mdadm /dev/md0 --add /dev/sda1
* fsck filesystem and expect to lose files where there were bad blocks
* wait for new drive (special delivery - tomorrow morning)
* insert new drive as /dev/sdd
* mdadm /dev/md0 --add /dev/sdd1

or am I wasting my time?

David
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]


  Powered by Linux