[PATCH md 0 of 2] Introduction

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Two patches for md in 2.6.9-rc1-mm2

The first adds support for notifying user-space of events in md.

The mechanism is very simple.  A reader of /proc/mdstat can select for
"exceptional" events.  When select/poll indicates one of these, the 
reader should re-read /proc/mdstat from the top looking for changes, and then
select again.

If the reader opens for write as well (O_RDWR) (only root can do
this), then it indicates that it is prepared to take remedial action.
This is currently only relevant for multipath.  On last-drive-failure,
if there is a reader of /proc/mdstat that has an open for write, then
multipath will wait for that reader to add a new drive or take other
action before resubmitting the failed requests.

The second patch just fixes a counter in raid5/6 which could get out-by-one, and so
produce confusing messages.

(I think I sent a single item of junk just before this, sorry about that.  Please
ignore it).

NeilBrown

-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]