On 19.02.2018 15:48, Tanu Kaskinen wrote: > pa_sink_get_state() is supposed to be used from the main thread. In this > case it doesn't really matter, because the SET_STATE handler is executed > while the main thread is waiting, but since the state is available also > in thread_info, let's use that. All other modules use thread_info.state > too, so at least this change improves consistency. > --- > src/modules/module-null-sink.c | 2 +- > src/modules/module-pipe-sink.c | 4 ++-- > 2 files changed, 3 insertions(+), 3 deletions(-) > > diff --git a/src/modules/module-null-sink.c b/src/modules/module-null-sink.c > index 25b0f3091..c29722fad 100644 > --- a/src/modules/module-null-sink.c > +++ b/src/modules/module-null-sink.c > @@ -91,7 +91,7 @@ static int sink_process_msg( > switch (code) { > case PA_SINK_MESSAGE_SET_STATE: > > - if (pa_sink_get_state(u->sink) == PA_SINK_SUSPENDED || pa_sink_get_state(u->sink) == PA_SINK_INIT) { > + if (u->sink->thread_info.state == PA_SINK_SUSPENDED || u->sink->thread_info.state == PA_SINK_INIT) { > if (PA_PTR_TO_UINT(data) == PA_SINK_RUNNING || PA_PTR_TO_UINT(data) == PA_SINK_IDLE) > u->timestamp = pa_rtclock_now(); > } > diff --git a/src/modules/module-pipe-sink.c b/src/modules/module-pipe-sink.c > index a2074c1f2..fc909af15 100644 > --- a/src/modules/module-pipe-sink.c > +++ b/src/modules/module-pipe-sink.c > @@ -111,10 +111,10 @@ static int sink_process_msg(pa_msgobject *o, int code, void *data, int64_t offse > > switch (code) { > case PA_SINK_MESSAGE_SET_STATE: > - if (pa_sink_get_state(u->sink) == PA_SINK_SUSPENDED || pa_sink_get_state(u->sink) == PA_SINK_INIT) { > + if (u->sink->thread_info.state == PA_SINK_SUSPENDED || u->sink->thread_info.state == PA_SINK_INIT) { > if (PA_PTR_TO_UINT(data) == PA_SINK_RUNNING || PA_PTR_TO_UINT(data) == PA_SINK_IDLE) > u->timestamp = pa_rtclock_now(); > - } else if (pa_sink_get_state(u->sink) == PA_SINK_RUNNING || pa_sink_get_state(u->sink) == PA_SINK_IDLE) { > + } else if (u->sink->thread_info.state == PA_SINK_RUNNING || u->sink->thread_info.state == PA_SINK_IDLE) { > if (PA_PTR_TO_UINT(data) == PA_SINK_SUSPENDED) { > /* Clear potential FIFO error flag */ > u->fifo_error = false; As remarked by Raman Shyshniou on one of my patches you could use the PA_SINK_IS_OPENED() macro instead of x == PA_SINK_RUNNING || x == PA_SINK_IDLE Otherwise looks good.