07.10.2014 19:55, Tanu Kaskinen wrote: > The default maximum latency is 10 seconds, which is not good, > especially since the tunnel sink doesn't support rewinding. Due to the > lack of rewinding, e.g. volume changes take a long time with large > latencies. ACK in principle, but this limit for the maximum non-rewindable latency should come from a single source and should not be defined anew for each non-rewindable sink. And maybe it needs to be configurable from daemon.conf. IMHO the patch can be applied now in its current form, and the changes suggested above can go into a separate commit. > --- > Changes in v2: removed the Change-Id from the commit message. > > > src/modules/module-tunnel-sink-new.c | 2 ++ > 1 file changed, 2 insertions(+) > > diff --git a/src/modules/module-tunnel-sink-new.c b/src/modules/module-tunnel-sink-new.c > index c74a7c1..2a91be9 100644 > --- a/src/modules/module-tunnel-sink-new.c > +++ b/src/modules/module-tunnel-sink-new.c > @@ -60,6 +60,7 @@ PA_MODULE_USAGE( > "cookie=<cookie file path>" > ); > > +#define MAX_LATENCY_USEC (200 * PA_USEC_PER_MSEC) > #define TUNNEL_THREAD_FAILED_MAINLOOP 1 > > static void stream_state_cb(pa_stream *stream, void *userdata); > @@ -525,6 +526,7 @@ int pa__init(pa_module *m) { > u->sink->userdata = u; > u->sink->parent.process_msg = sink_process_msg_cb; > u->sink->update_requested_latency = sink_update_requested_latency_cb; > + pa_sink_set_latency_range(u->sink, 0, MAX_LATENCY_USEC); > > /* set thread message queue */ > pa_sink_set_asyncmsgq(u->sink, u->thread_mq->inq);