> 04.08.2014 18:40, Peter Meerwald wrote: > > see https://libav.org/doxygen/master/group__lavr.html > > > > Signed-off-by: Peter Meerwald <pmeerw at pmeerw.net> > > Signed-off-by: poljar (Damir Jeli?) <poljarinho at gmail.com> > > --- > > configure.ac | 17 +++++ > > src/Makefile.am | 6 ++ > > src/pulsecore/resampler.c | 14 +++- > > src/pulsecore/resampler.h | 2 + > > src/pulsecore/resampler/lavr.c | 160 > +++++++++++++++++++++++++++++++++++++++++ > > 5 files changed, 198 insertions(+), 1 deletion(-) > > create mode 100644 src/pulsecore/resampler/lavr.c > > Summary of the too-big message with the spectrogram: I suspect an > implementation error. This resampler behaves incorrectly for the 44100 > -> 48000 Hz when given a sine wave with frequency higher than 11025 Hz. > A proper resampler would output a sine wave with the same frequency as > input. This one creates a sine wave of a different frequency. this is interesting; I think the libav people would love to hear :) p. -- Peter Meerwald +43-664-2444418 (mobile)