Since the RAOP sink supports only some formats and channel counts, we shouldn't blindly use pa_core.default_sample_spec. This patch changes things so that we default to PA_SAMPLE_S16NE and 2 channels, and only take the sample rate from pa_core.default_sample_spec. --- src/modules/raop/module-raop-sink.c | 8 +++++--- 1 file changed, 5 insertions(+), 3 deletions(-) diff --git a/src/modules/raop/module-raop-sink.c b/src/modules/raop/module-raop-sink.c index 2d08645..13036d9 100644 --- a/src/modules/raop/module-raop-sink.c +++ b/src/modules/raop/module-raop-sink.c @@ -518,15 +518,17 @@ int pa__init(pa_module*m) { goto fail; } - ss = m->core->default_sample_spec; + ss.format = PA_SAMPLE_S16NE; + ss.channels = 2; + ss.rate = m->core->default_sample_spec.rate; if (pa_modargs_get_sample_spec(ma, &ss) < 0) { pa_log("invalid sample format specification"); goto fail; } - if ((/*ss.format != PA_SAMPLE_U8 &&*/ ss.format != PA_SAMPLE_S16NE) || + if ((ss.format != PA_SAMPLE_S16NE) || (ss.channels > 2)) { - pa_log("sample type support is limited to mono/stereo and U8 or S16NE sample data"); + pa_log("sample type support is limited to mono/stereo and S16NE sample data"); goto fail; } -- 1.9.3