Hi David, On Tue, Jan 29, 2013 at 8:10 AM, David Henningsson <david.henningsson at canonical.com> wrote: > On 01/28/2013 05:59 PM, Mikel Astiz wrote: >> >> From: Mikel Astiz <mikel.astiz at bmw-carit.de> >> >> Extend the reserve-monitor API with a registration mechanism to keep >> track of existing private connections. This is necessary because the >> monitor should not consider it busy if a device has been owned by us. > > > Am I missing an earlier thread here, or why do we need this? Isn't the > existing checks (that I pushed to 3.0 stable) enough to give a correct > "busy" result? The "busy" result is working fine except if private D-Bus connections are used, as introduced in patch v0 2/2. In this case the unique name of the bus differs compared to the bus used by the monitor, but we still want to consider it as non-busy. I'll make this more clear in the header-file comment in v1, as suggested by Tanu. Cheers, Mikel