When the interface mode is SGMII and act_link_an_mode is MLO_AN_INBAND, switching to the 2500BASE-X interface mode will trigger phylink_major_config, and act_link_an_mode will be updated to MLO_AN_PHY in phylink_pcs_neg_mode when the PCS does not support in-band mode. The MAC and PCS will configure according to the interface mode and act_link_an_mode. However, when the interface goes link down and then link up again, the MAC will attempt to attach the PHY. The interface mode remains as 2500BASE-X, but cfg_link_an_mode still holds MLO_AN_INBAND. This causes a failure to attach the PHY. This patch uses act_link_an_mode to determine if there is a PHY to attach. Signed-off-by: Choong Yong Liang <yong.liang.choong@xxxxxxxxxxxxxxx> --- drivers/net/phy/phylink.c | 10 ++++++---- 1 file changed, 6 insertions(+), 4 deletions(-) diff --git a/drivers/net/phy/phylink.c b/drivers/net/phy/phylink.c index 214b62fba991..b0f9725e0494 100644 --- a/drivers/net/phy/phylink.c +++ b/drivers/net/phy/phylink.c @@ -1903,6 +1903,7 @@ int phylink_set_fixed_link(struct phylink *pl, pl->cfg_link_an_mode = MLO_AN_FIXED; pl->req_link_an_mode = pl->cfg_link_an_mode; + pl->act_link_an_mode = pl->cfg_link_an_mode; return 0; } @@ -2002,6 +2003,7 @@ struct phylink *phylink_create(struct phylink_config *config, } pl->req_link_an_mode = pl->cfg_link_an_mode; + pl->act_link_an_mode = pl->cfg_link_an_mode; ret = phylink_register_sfp(pl, fwnode); if (ret < 0) { @@ -2044,8 +2046,8 @@ EXPORT_SYMBOL_GPL(phylink_destroy); */ bool phylink_expects_phy(struct phylink *pl) { - if (pl->cfg_link_an_mode == MLO_AN_FIXED || - (pl->cfg_link_an_mode == MLO_AN_INBAND && + if (pl->act_link_an_mode == MLO_AN_FIXED || + (pl->act_link_an_mode == MLO_AN_INBAND && phy_interface_mode_is_8023z(pl->link_config.interface))) return false; return true; @@ -2280,8 +2282,8 @@ static int phylink_attach_phy(struct phylink *pl, struct phy_device *phy, { u32 flags = 0; - if (WARN_ON(pl->cfg_link_an_mode == MLO_AN_FIXED || - (pl->cfg_link_an_mode == MLO_AN_INBAND && + if (WARN_ON(pl->act_link_an_mode == MLO_AN_FIXED || + (pl->act_link_an_mode == MLO_AN_INBAND && phy_interface_mode_is_8023z(interface) && !pl->sfp_bus))) return -EINVAL; -- 2.34.1