Am Tue, 18 Jul 2023 08:07:52 -0700 schrieb Guenter Roeck <linux@xxxxxxxxxxxx>: > On Tue, Jul 18, 2023 at 12:52:11PM +0200, Henning Schild wrote: > > If a user did choose to enable Siemens Simatic platform support they > > likely want that driver to be enabled without having to flip more > > config switches. So we make the watchdog driver config switch > > default to the platform driver switches value. > > > > Signed-off-by: Henning Schild <henning.schild@xxxxxxxxxxx> > > --- > > drivers/watchdog/Kconfig | 1 + > > 1 file changed, 1 insertion(+) > > > > diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig > > index ee97d89dfc11..ccdbd1109a32 100644 > > --- a/drivers/watchdog/Kconfig > > +++ b/drivers/watchdog/Kconfig > > @@ -1681,6 +1681,7 @@ config NIC7018_WDT > > config SIEMENS_SIMATIC_IPC_WDT > > tristate "Siemens Simatic IPC Watchdog" > > depends on SIEMENS_SIMATIC_IPC > > + default SIEMENS_SIMATIC_IPC > > Why not just "default y" ? That does the same (it will be set to m if > SIEMENS_SIMATIC_IPC=m) without the complexity. I see. Thanks! In that case i will go for "default y" and not "default m" which i wrote about in the other mail. Henning > Guenter > > > select WATCHDOG_CORE > > select P2SB > > help > > -- > > 2.41.0 > >