This is an improved version of the battery charge control for Toshiba Satellite Z830. The full background is available in the two emails linked below, but a short summary will follow, including only what is relevant for battery charge control. Background (from link 1) ========== The Toshiba Satellite/Portege Z830 supports not charging the battery fully in order to prolong battery life. Unlike for example ThinkPads where this control is granular here it is just off/on. When off it charges to 100%. When on it charges to about 80%. According to the Windows program used to control the feature the setting will not take effect until the battery has been discharged to around 50%. However, in my testing it takes effect as soon as the charge drops below 80%. On Windows Toshiba branded this feature as "Eco charging" In the following example ACPI calls I will use the following newly defined constants: #define HCI_BATTERY_CHARGE_MODE 0xba #define BATTERY_CHARGE_FULL 0 #define BATTERY_CHARGE_80_PERCENT 1 To set the feature: {HCI_SET, HCI_BATTERY_CHARGE_MODE, charge_mode, 0, 0, 0} To query for the existence of the feature: {HCI_GET, HCI_BATTERY_CHARGE_MODE, 0, 0, 0, 0} To read the feature: {HCI_GET, HCI_BATTERY_CHARGE_MODE, 0, 0, 0, 1} The read may need to be retried if TOS_DATA_NOT_AVAILABLE is returned as the status code. This rarely happens (I have never observed it on Linux), but I have seen it happen under Windows once, and the software did retry it. Improvements ============ As discussed in link 2 & 3 below, the original approach was suboptimal. This patch series instead consists of two patches. The first patch implements detecting the feature as well as internal getter/setter methods. The second patch adds battery hooks (heavily based on the code for this in thinkpad_acpi) which creates the standard charge_control_end_threshold file under /sys/class/power_supply/BAT1. Side note: There is no BAT0 on this Toshiba, I'm not sure why the numbering ends up starting from 1 instead of 0 here. This differs from my Thinkpads, where the numbering starts from 0, with BAT1 being the second battery. However, I haven't spent much effort investigating this, as it did not seem important. Patch 3 updates the ABI test documentation as suggested by Hans de Goede. Note that only the charge_control_end_threshold is updated, as this is the only limit supported by the Toshiba Z830. Possibly charge_control_start_threshold should also be updated similarly, or would it be better to wait for an actual example of this in the wild first? Link (1): https://www.spinics.net/lists/platform-driver-x86/msg34314.html Link (2): https://www.spinics.net/lists/platform-driver-x86/msg34354.html Link (3): https://www.spinics.net/lists/platform-driver-x86/msg34320.html Arvid Norlander (3): platform/x86: Battery charge mode in toshiba_acpi (internals) platform/x86: Battery charge mode in toshiba_acpi (sysfs) docs: ABI: charge_control_end_threshold may not support all values Documentation/ABI/testing/sysfs-class-power | 5 +- drivers/platform/x86/toshiba_acpi.c | 162 ++++++++++++++++++++ 2 files changed, 166 insertions(+), 1 deletion(-) base-commit: 1c23f9e627a7b412978b4e852793c5e3c3efc555 -- 2.37.2