On Mon, Apr 29, 2019 at 6:01 PM Hans de Goede <hdegoede@xxxxxxxxxx> wrote: > > The Lex 3I380D industrial PC has 4 ethernet controllers on board > which need pmc_plt_clk0 - 3 to function, add it to the critclk_systems > DMI table, so that drivers/clk/x86/clk-pmc-atom.c will mark the clocks > as CLK_CRITICAL and they will not get turned off. > Acked-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx> supposedly to go via CLK tree. P.S. If you want it through PDx86, I need immutable branch / tag from CLK. > Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") > Reported-and-tested-by: Semyon Verchenko <semverchenko@xxxxxxxxxxxx> > Signed-off-by: Hans de Goede <hdegoede@xxxxxxxxxx> > --- > drivers/platform/x86/pmc_atom.c | 9 +++++++++ > 1 file changed, 9 insertions(+) > > diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c > index 3a635ea09b8a..2910845b7cdd 100644 > --- a/drivers/platform/x86/pmc_atom.c > +++ b/drivers/platform/x86/pmc_atom.c > @@ -407,12 +407,21 @@ static int pmc_dbgfs_register(struct pmc_dev *pmc) > */ > static const struct dmi_system_id critclk_systems[] = { > { > + /* pmc_plt_clk0 is used for an external HSIC USB HUB */ > .ident = "MPL CEC1x", > .matches = { > DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"), > DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"), > }, > }, > + { > + /* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */ > + .ident = "Lex 3I380D", > + .matches = { > + DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"), > + DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"), > + }, > + }, > { /*sentinel*/ } > }; > > -- > 2.21.0 > -- With Best Regards, Andy Shevchenko