Hi, On Fri, Feb 09, 2018 at 10:22:54AM +0100, Rafael J. Wysocki wrote: > On Thu, Feb 8, 2018 at 11:03 PM, Sebastian Reichel <sre@xxxxxxxxxx> wrote: > > Hi, > > > > On Wed, Feb 07, 2018 at 03:58:44PM +0100, Ognjen Galic wrote: > >> 1) Charge start threshold > >> /sys/class/power_supply/BATN/charge_start_threshold > >> > >> Valid values are [0, 99]. A value of 0 turns off the > >> start threshold wear control. > >> > >> 2) Charge stop threshold > >> /sys/class/power_supply/BATN/charge_stop_threshold > >> > >> Valid values are [1, 100]. A value of 100 turns off > >> the stop threshold wear control. This must be > >> configured first. > > > > This is a new sysfs file, that should be documented. > > Right, I should have remembered about that, sorry. > > > Also this looks pretty generic. Just introduce new POWER_SUPPLY_PROP_ > > entries for start/stop charging threshold and use them. > > What about doing this as a follow-up? Fine with me. -- Sebastian