Obviously, I have done this to improve write performance for the update
each week. My question is if I install a 3ware or similar card to
replace my current software RAID 1 configuration, am I going to see a
very large improvement? If so, what would be a ball park figure?
Well that entirely depends on what level...
1. I would suggest LSI 150-6 not 3ware
Why?
Because 3ware does not make a midrange card that has a battery backed
cache :). That is the only reason. 3ware makes good stuff.
So anyway... LSI150-6 with Battery Backed cache option. Put 6 drives
on it with a RAID 10 array, turn on write cache and you should have
a hauling drive.
Joshua D. Drake
*Benjamin Arai*
barai@xxxxxxxxxx <mailto:barai@xxxxxxxxxx>
http://www.benjaminarai.com <http://www.benjaminarai.com/>
--
The PostgreSQL Company - Command Prompt, Inc. 1.503.667.4564
PostgreSQL Replication, Consulting, Custom Development, 24x7 support
Managed Services, Shared and Dedicated Hosting
Co-Authors: plPHP, plPerlNG - http://www.commandprompt.com/