Getting below error while running a background job for inserting 1 Million records.
Can I get some help ?
cp: error writing '/BackupVolume/hisDbBackup/WALs/0000000200000AE6000000B9': No space left on device
2020-12-17 21:55:26 +04 [55822]: user=,db=,app=,client= LOG: archive command failed with exit code 1
2020-12-17 21:55:26 +04 [55822]: user=,db=,app=,client= DETAIL: The failed archive command was: test ! -f /BackupVolume/dbWALBack/WALs/0000000200000AE6000000B9 && cp pg_wal/0000000200000AE6000000B9 /BackupVolume/hisDbBackup/WALs/0000000200000AE6000000B9
2020-12-17 21:53:56 +04 [84225]: user=AstDBA,db=AST-PROD,app=[unknown],client=172.18.200.100 HINT: In a moment you should be able to reconnect to the database and repeat your command.
2020-12-17 21:53:56 +04 [51102]: user=AstDBA,db=AST-PROD,app=[unknown],client=172.18.200.100 WARNING: terminating connection because of crash of another server process
2020-12-17 21:53:56 +04 [51102]: user=AstDBA,db=AST-PROD,app=[unknown],client=172.18.200.100 DETAIL: The postmaster has commanded this server process to roll back the current transaction and exit, because another server process exited abnormally and possibly corrupted shared memory.
2020-12-17 21:55:20 +04 [55808]: user=replicator,db=[unknown],app=[unknown],client=172.18.200.144 FATAL: the database system is in recovery mode
2020-12-17 21:55:25 +04 [55828]: user=replicator,db=[unknown],app=walreceiver,client=172.18.200.148 ERROR: requested starting point AEA/A2000000 is ahead of the WAL flush position of this server AEA/A1FFFA50
2020-12-17 21:55:25 +04 [55827]: user=replicator,db=[unknown],app=walreceiver,client=172.18.200.147 ERROR: requested starting point AEA/A2000000 is ahead of the WAL flush position of this server AEA/A1FFFA50
2020-12-17 21:55:25 +04 [55829]: user=replicator,db=[unknown],app=walreceiver,client=172.18.200.145 ERROR: requested starting point AEA/A2000000 is ahead of the WAL flush position of this server AEA/A1FFFA50
2020-12-17 21:55:25 +04 [55830]: user=replicator,db=[unknown],app=walreceiver,client=172.18.200.146 ERROR: requested starting point AEA/A2000000 is ahead of the WAL flush position of this server AEA/A1FFFA50
2020-12-17 21:55:25 +04 [55831]: user=replicator,db=[unknown],app=walreceiver,client=172.18.200.144 ERROR: requested starting point AEA/A2000000 is ahead of the WAL flush position of this server AEA/A1FFFA50
Thanks
Sreejith
Solutions for Care Anywhere
dWise HealthCare IT Solutions Pvt. Ltd. | www.lifetrenz.com
Disclaimer: The information and attachments contained in this email are intended for exclusive use of the addressee(s) and may contain confidential or privileged information. If you are not the intended recipient, please notify the sender immediately and destroy all copies of this message and any attachments. The views expressed in this email are, unless otherwise stated, those of the author and not those of dWise HealthCare IT Solutions or its management.