On Wed, Aug 09, 2006 at 12:29:50PM +0200, Rodolfo Giometti wrote: > > mmc0: starting CMD2 arg 00000000 flags 00000067 > mmc0: req done (CMD2): 0/0/0: 1d41444d 494e4953 10310001 9a005500 Ok. This the CID number. > mmc0: starting CMD3 arg 00000000 flags 00000065 > mmc0: req done (CMD3): 0/0/0: 019a0055 00000000 00000000 00000000 And this is the RCA. > mmc0: host does not support reading read-only switch. assuming write-enable. > mmc0: starting CMD2 arg 00000000 flags 00000067 > mmc0: req done (CMD2): 1/0/0: 00000000 00000000 00000000 00000000 > mmc0: req done (CMD2): 1/0/0: 00000000 00000000 00000000 00000000 > mmc0: req done (CMD2): 1/0/0: 00000000 00000000 00000000 00000000 > mmc0: req done (CMD2): 1/0/0: 00000000 00000000 00000000 00000000 > mmc0: clock 450000Hz busmode 2 powermode 2 cs 0 Vdd 15 width 0 > mmc0: starting CMD9 arg 019a0000 flags 00000007 > mmc0: req done (CMD9): 1/0/0: 00000000 00000000 00000000 00000000 > mmc0: req done (CMD9): 1/0/0: 00000000 00000000 00000000 00000000 > mmc0: req done (CMD9): 1/0/0: 00000000 00000000 00000000 00000000 > mmc0: req done (CMD9): 1/0/0: 00000000 00000000 00000000 00000000 Here is the problem! I get no answer to CMD9 (CSD request) due a timeout (sd0_status=0x3028080). Rodolfo -- GNU/Linux Solutions e-mail: giometti@xxxxxxxxxxxx Linux Device Driver giometti@xxxxxxxxx Embedded Systems giometti@xxxxxxxx UNIX programming phone: +39 349 2432127