On Thu, 23 Dec 2010, Ross Boylan wrote: > What happens if you vgmerge 2 VG's and they have different physical > extent sizes? The man page says it should fail. It's possible that if everything lines up, it automatically changes the extent size of either the source or destination VG. It is possible to change the PE size with vgchange (some lvresizing/pvmoving may be required and must be done manually). -- Stuart D. Gathman <stuart@bmsi.com> Business Management Systems Inc. Phone: 703 591-0911 Fax: 703 591-6154 "Confutatis maledictis, flammis acribus addictis" - background song for a Microsoft sponsored "Where do you want to go from here?" commercial. _______________________________________________ linux-lvm mailing list linux-lvm@redhat.com https://www.redhat.com/mailman/listinfo/linux-lvm read the LVM HOW-TO at http://tldp.org/HOWTO/LVM-HOWTO/