On 07/04/2015 11:57 PM, Jean Delvare wrote:
On Sat, 04 Jul 2015 11:08:36 -0700, Guenter Roeck wrote:
Hi Constantine,
On 07/04/2015 07:57 AM, Constantine Shulyupin wrote:
Added fan output control registers.
Modes of operation are PWM (default) and DC.
Another note: Since you mention DC vs. pwm mode, have you
considered adding pwm[123]_mode attributes to report the
selected mode ?
If you do, please make sure these attributes are read-only.
They are.
Guenter