On 07/04/2015 11:49 AM, Constantine Shulyupin wrote:
Added fan output control registers. Modes of operation are PWM (default) and DC. Introduced show_pwm, store_pwm, nct7802_pwm_attrs, nct7802_pwm_group. --- Change log: Fixed in v2: - renamed fanX_output to pwmX - introduced nct7802_pwm_group and nct7802_pwm_attrs - renamed show_dec to show_pwd - used kstrtou8 instead kstrtouint Fixed in v3: - spilt functions declarations to fit 80 columns - removed unnecessary initializations - rearranged variable declarations - shortened return expression - renamed store_u8 to store_pwm Fixed in v4: - compilation error: missing val Signed-off-by: Constantine Shulyupin <const@xxxxxxxxxxxxx>
Applied to -next. Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors