Re: [PATCH] fix nct7802_temp_is_visible

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Constantine,

On 06/24/2015 03:47 PM, Constantine Shulyupin wrote:
From: const <const@xxxxxxxxxxxxx>

Fixed registers are invisible only when registers' mode is 0

Signed-off-by: Constantine Shulyupin <const@xxxxxxxxxxxxx>
---
  drivers/hwmon/nct7802.c | 8 +++-----
  1 file changed, 3 insertions(+), 5 deletions(-)

diff --git a/drivers/hwmon/nct7802.c b/drivers/hwmon/nct7802.c
index ec56782..65e40c2 100644
--- a/drivers/hwmon/nct7802.c
+++ b/drivers/hwmon/nct7802.c
@@ -541,13 +541,11 @@ static umode_t nct7802_temp_is_visible(struct kobject *kobj,
  	if (err < 0)
  		return 0;

-	if (index < 9 &&
-	    (reg & 03) != 0x01 && (reg & 0x03) != 0x02)		/* RD1 */
+	if (index < 9 && !(reg & 0x03))			/* RD1 */
  		return 0;
-	if (index >= 9 && index < 18 &&
-	    (reg & 0x0c) != 0x04 && (reg & 0x0c) != 0x08)	/* RD2 */
+	if (index >= 9 && index < 18 && !(reg & 0x0c))	/* RD2 */
  		return 0;
-	if (index >= 18 && index < 27 && (reg & 0x30) != 0x10)	/* RD3 */
+	if (index >= 18 && index < 27 && !(reg & 0x30))	/* RD3 */

11b sets a sensor to voltage sense mode, not temperature mode.
This is what the inX attributes are for. We can not just display a
random temperature value if a sensor is configured to measure a voltage.

According to my datasheet, 01b (0x10 shifted) is reserved for RD3.
So there is a bug, but it is

	if (index >= 18 && index < 27 && (reg & 0x30) != 0x10)	/* RD3 */
which should be
	if (index >= 18 && index < 27 && (reg & 0x30) != 0x20)	/* RD3 */

Can you send an updated patch ?

Thanks,
Guenter


_______________________________________________
lm-sensors mailing list
lm-sensors@xxxxxxxxxxxxxx
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors



[Index of Archives]     [Linux Kernel]     [Linux Hardware Monitoring]     [Linux USB Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Yosemite Backpacking]

  Powered by Linux