On Thu, Aug 28, 2014 at 10:45:43AM -0700, Robert Coulson wrote: > From: Robert Coulson <rob.coulson@xxxxxxxxx> > > After the conversion rate is changed, the zbits are not updated, > but should be, since they are used later in the set_temp function. > > Fixes: a50d9a4d9ad3 ("hwmon: (ds1621) Fix temperature rounding operations") > Reported-by: Murat Ilsever <murat.ilsever@xxxxxxxxx> > Signed-off-by: Robert Coulson <rob.coulson@xxxxxxxxx> > Applied. Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors