On platforms with sizeof(int) < sizeof(long), writing a temperature limit larger than MAXINT will result in unpredictable limit values written to the chip. Avoid auto-conversion from long to int to fix the problem. The hysteresis temperature range depends on the value of data->temp[attr->index], since val is subtracted from it. Use a wider clamp, [-120000, 220000] should do to cover the possible range. Also uses clamp_val to simplify the code a bit. Signed-off-by: Axel Lin <axel.lin@xxxxxxxxxx> --- drivers/hwmon/lm92.c | 11 +++++------ 1 file changed, 5 insertions(+), 6 deletions(-) diff --git a/drivers/hwmon/lm92.c b/drivers/hwmon/lm92.c index d2060e2..08a261d 100644 --- a/drivers/hwmon/lm92.c +++ b/drivers/hwmon/lm92.c @@ -74,12 +74,9 @@ static inline int TEMP_FROM_REG(s16 reg) return reg / 8 * 625 / 10; } -static inline s16 TEMP_TO_REG(int val) +static inline s16 TEMP_TO_REG(long val) { - if (val <= -60000) - return -60000 * 10 / 625 * 8; - if (val >= 160000) - return 160000 * 10 / 625 * 8; + val = clamp_val(val, -60000, 160000); return val * 10 / 625 * 8; } @@ -206,8 +203,10 @@ static ssize_t set_temp_hyst(struct device *dev, if (err) return err; + val = clamp_val(val, -120000, 220000); mutex_lock(&data->update_lock); - data->temp[t_hyst] = TEMP_FROM_REG(data->temp[attr->index]) - val; + data->temp[t_hyst] = + TEMP_TO_REG(TEMP_FROM_REG(data->temp[attr->index]) - val); i2c_smbus_write_word_swapped(client, LM92_REG_TEMP_HYST, TEMP_TO_REG(data->temp[t_hyst])); mutex_unlock(&data->update_lock); -- 1.9.1 _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors