On Sat, Jul 19, 2014 at 12:00:34AM +0200, Jean Delvare wrote: > On Fri, 18 Jul 2014 12:11:54 -0700, Guenter Roeck wrote: > > Temperature limit clamps are applied after converting the temperature > > from milli-degrees C to degrees C, so either the clamp limit needs > > to be specified in degrees C, not milli-degrees C, or clamping must > > happen before converting to degrees C. Use the latter method to avoid > > overflows. > > > > vrm is an u8, so the written value needs to be limited to [0, 255]. > > > > Cc: Axel Lin <axel.lin@xxxxxxxxxx> > > Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx> > > --- > > v2: Clamp temperature limit first, then scale, to avoid overflows > > Don't clamp vrm but return an error if it is out of range. > > Fix typo in description > > > > drivers/hwmon/smsc47m192.c | 4 +++- > > 1 file changed, 3 insertions(+), 1 deletion(-) > > [ ... ] > > Looks good. > > Reviewed-by: Jean Delvare <jdelvare@xxxxxxx> > Thanks! Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors